• HTFS 400-P
  • HTFS 400-P
  • HTFS 400-P
  • HTFS 400-P
  • HTFS 400-P
Срок поставки и цена – по запросу

CURRENT TRANSDUCER; Operating Frequency Range:DC to 50kHz; Sensor Output1:Voltage; Response Time:7µs; SVHC:No SVHC (15-Dec-2010); Accuracy:1%; Accuracy %:1%; Current Consumption:22mA; Current Range AC:DC, AC, Pulsed, Mixed; Current Range DC:DC, AC, Pulsed, Mixed; Current Rating:400A; External Depth:46mm; External Length / Height:16.5mm; External Width:40mm; Flammability Rating:UL 94-V0; Frequency Max:20kHz; Frequency Min:0Hz; Linearity:0.5%; Operating Temperature Max:105°C; Operating Temperature Min:-40°C; Output Type:Instantaneous; Series:HTFS; Standard:EN 50178(97-10-01); Supply Voltage:+5V; Transducer Function:Electronic Measurement of Currents; Weight:58g

Sensor OutputVoltage
Supply Voltage DC Min4.75V
Supply Voltage DC Max5.25V
Current Measuring Range DC-600A to 600A
Current Measuring Range AC-600A to 600A
Response Time7µs
Accuracy %1%
Product RangeHTFS Series
SVHCNo SVHC (12-Jan-2017)
Accuracy1%
Current Consumption22mA
Current Range ACDC, AC, Pulsed, Mixed
Current Range DCDC, AC, Pulsed, Mixed
Current Rating400A
External Depth46mm
External Length / Height16.5mm
External Width40mm
Flammability RatingUL 94-V0
Frequency Max20kHz
Frequency Min0Hz
Linearity0.5%
Operating Temperature Max105°C
Operating Temperature Min-40°C
Output TypeInstantaneous
StandardEN 50178(97-10-01)
Supply Voltage+5V
Supply Voltage Range DC4.75V to 5.25V
Transducer FunctionCurrent
Weight58g
supply_voltage_dc5.00 V
weight58.0 g
rohs_statusCompliant
reach_svhc_complianceNo SVHC
flammability_ratingUL 94 V-0
mounting_styleThrough Hole
packagingTube
current_rating400 A
Показать остальные свойства..